Laurel
Electronics provides digital panel meters / controllers,
totalizers, counters, loop-powered meters, temperature meters,
for all types of transducers or process indication &
control. |
|
|
|
|
|
Stopwatch Input
Modbus or Laurel ASCII Protocol Serial I/O Transmitter
|

|

Resolution to 0.2 µs. Duration to 999,999 hrs.
DIN Rail mounted, digitally programmable.
|
Click
to Order Stopwatch Input Modbus Transmitter
|
|
Features |
|
Selectable Modbus
or Laurel ASCII protocol.
|
Modbus
RTU or ASCII modes, 2-wire connection,
up to 247 digital addresses.
|
|
Times
single event time or accumulated time of all events.
|
Timing
resolution to 0.2
µs.
|
| 0.2,
2, 20, 200, 300V & 600V DC voltage ranges.
|
2,
20, 200 mA and 5A DC current ranges.
|
| Timing
duration to 999,999 hrs
|
Selectable
H, M or S decimal format.
|
| Selectable
HH.MM.SS clock format.
|
Inputs
from NPN or PNP proximity switches, contact closures,
digital logic, or magnetic pickups down to 12 mV.
|
| Triggers
on positive or negative pulse edges.
|
Isolated
5V, 10V or 15V dc excitation output to power transducers
|
| DIN
rail mount package only 22.5 mm thick.
|
Detachable screw clamp plug
connectors
|
| Easy
setup using Laurel's PC-based Instrument
Setup Software.
|
Optional dual solid state
relays for alarm or control.
|
|
|
Description
|
|
Stopwatch
Operation

The Laureate
TM Series serial output stopwatch transmitter performs
all of the functions of the Laureate panel mount stopwatch,
except for the display. The data retrieved via serial
commands can be the time of individual events (Item #1)
which produce start and stop pulses, or accumulated time of
multiple events (Item #2). The highest resolution is 0.2 µs,
making the transmitter ideal for fast events. The longest
timing interval is 999,999 hrs. For long events, the output
is updated continuously during timing. There are two primary
timing modes:
- A-A Stopwatch
Mode. Time
is measured between a start pulse and a stop pulse, both
on Channel A, from either the positive or negative
edges.
- A-B Stopwatch
Mode. Time is measured
between a start pulse on Channel A (positive or negative
edge) and a stop pulse on Channel B (positive or
negative edge). This mode allows inputs from different
sources. In addition, the A and B inputs can be tied
together to start the stopwatch
with one polarity and stop it with the other polarity.
Event time (Item #1)
is measured by counting 5.5 MHz clock pulses from a
calibrated quartz crystal. The
stopwatch output is updated during timing at a rate
controlled by a gate time, up to 25/sec. Time is reset to
zero when the next start pulse occurs. Accumulated time from
multiple events up to 999,999 hours (Item #2) can also be
tracked.
Universal
Signal Conditioner
The
dual-channel signal conditioner used for pulse detection
accepts inputs from proximity switches with PNP or NPN
output, TTL or CMOS logic, magnetic pickups, contact
closures, and other signals from 12 mV to 250 Vac. Jumper
selections provide optimum operation for different sensor
types and noise conditions. A built-in isolated 5V, 10V or
15V dc excitation supply can power proximity switches and
other sensors, and eliminate the need for an external power
supply.
Serial
Data I/O & Programming
Laureate TM
Series transmitters send data as a serial digital signal.
RS485 or RS232 signal levels are jumper selectable and can
each be associated with either the Modbus protocol or
Laurel’s simpler Laurel ASCII protocol.
- Modbus protocol
operation
is fully compliant with the Modbus Over
Serial Line Specification V1.0 (2002) for 2-wire,
half-duplex connection. This includes RTU or ASCII
modes, addressing of up to 32 devices per RS485 line
without a repeater, and up to 247 digital addresses.
Modbus operation allows devices by different
manufacturers to be connected in parallel and be
addressed using the same protocol.
- Laurel’s Laurel ASCII
protocol
allows up to 31 Laureate devices to be
addressed on the same RS485 data line. It is simpler
than the Modbus protocol and is recommended when all
devices are Laureates. It also allows use of Laurel’s
datalogging software.
Transmitter
programming
is via the unit's three-terminal serial port
using Laurel's PC-based Instrument
Setup Software. This software can be downloaded from
this website at no charge. The required transmitter-to-PC
interface cable is available from Laurel (P/N CBL03).
Laurel's serial output transmitters and meters can also be
part of PC-based data logging systems using Laurel's Datalogging
Software, which operates under the Laurel ASCII
Protocol. A single software command switches between the
Modbus and Laurel ASCII Protocols.
Transmitter
Options
Options include
dual solid state relays for local alarm or control and an
isolated 4-20 mA or 10V (selectable) analog output,
effectively providing a linearized analog transmitter output
that tracks the reading that would be transmitted digitally.
The analog output provides 12-bit (4096 step) resolution of
the output span and is ultra-linear to within one bit. Its
accuracy is ±0.05% of span for all signal types, except for
AC rms, where accuracy is ±0.1%. Output isolation from
signal and power grounds is provided by a separate on-board
power supply, which can drive 20 mA into a 500 ohm load for
10V compliance. Output isolation eliminates problems caused
by ground loops.
DIN
Rail Mounting
Laureate
transmitters are housed in a 35 mm DIN rail case that is
only 22.5 mm (0.89") thick. Signal connections are via
detachable screw clamp plug connectors.
|
|
Click
to Order Stopwatch Input Modbus
Transmitter
|
|
Specifications
Laureate Serial I/O
Transmitter, Stopwatch Input
|
|
Pulse Input |
Types
Ch A Frequency, Max
Ch B Frequency, Max
Signal Ground
Minimum Signal
Maximum Signal
Maximum Frequency
Contact Debounce
Time Base Accuracy
Span Tempco
Long-term Drift |
AC, pulses from NPN, PNP transistors, contact
closures, magnetic pickups.
1 MHz.
250 kHz.
Common ground for channels A & B.
Nine ranges from (-12 to +12 mV) to (+1.25 to +2.1V).
250 Vac
1 MHz, 30 kHz, 250 Hz (selectable).
0, 3, 50 ms (selectable).
Quartz crystal calibrated to ±2 ppm.
±1 ppm/°C (typical)
±5 ppm/year |
|
Stopwatch Operation |
Timing Modes:
With CH A only
With CH A tied to CH B
With CH A and CH B
Timing Interval
Timing Resolution
Selectable Decimal Time
Selectable Clock Time
Output Update
Gate Time |
+ to + edge, or - to - edge.
+ to - edge, or - to + edge.
+ edge of A to + edge of B, + edge of A to - edge of B,
- edge to A to - edge of B, - edge of A to - edge of B
1 µs to 999,999 hrs
0.2 µs to 1 hr
999999 H, M or S format with decimal point
HH.MM.SS format
Gate time + 30 ms
Programmable from 10 ms to 199.99 s |
|
Serial I/O
(standard) |
Signal levels
Data Rates
Output Isolation
Serial Protocols
Devices on RS-485 Line
Modbus Addresses
Modbus Modes
Modbus Compliance |
RS485 (default) or RS232 (jumper selectable)
300, 600, 1200, 2400, 4800, 9600, 19200 baud
250V rms working, 2.3 kV rms per 1 min test.
Modbus RTU, Modbus ASCII, Laurel ASCII (selectable)
32 max without a repeater.
247 max
RTU or ASCII, 2-wire.
Modbus over Serial Line Specification V1.0 (2002).10V @ 60 mA, isolated to 50V from signal ground
5V @ 50 mA, isolated to 50V from signal ground
15V @ 60 mA, non-isolated |
|
Transducer Excitation Output
(standard) |
Jumper Selection 1
Jumper Selection 2
Jumper Selection 3 |
10V @ 60 mA, isolated to 50V from signal ground
5V @ 50 mA, isolated to 50V from signal ground
15V @ 60 mA, non-isolated |
|
Dual Relay Output
(optional) |
Relay Type
Load rating |
Two solid state relays, SPST, normally open,
Form A
120 mA at 130 Vac or 170 Vdc, 28 ohms series resistance. |
|
Analog Output
(optional) |
Output Levels
Compliance, 4-20 mA
Compliance, 0-10V
Output Resolution
Output Accuracy
Output Isolation |
0-20 mA, 4-20 mA or 0-10 Vdc (selectable)
10V ( 0-500 ohm load )
2 mA ( 5 kOhm load )
12 bits (4,096 steps)
±0.05% of output span
250V rms working, 2.3 kV rms per 1 minute test |
|
Power Input |
Standard power
Low power option
Frequency
Power Isolation |
95-240V AC ±10% or 90-300V DC
12-30V AC or 10-48V DC
DC or 47-63 Hz
250V rms working, 2.3 kV rms per 1 min test |
|
Mechanical |
Case Dimensions
Case Mounting
Electrical Connections |
120 x 101 x 22.5 mm
35 mm rail per DIN EN 50022
Detachable screw clamp plug connectors |
|
Environmental |
Operating Temperature
Storage Temperature
Relative Humidity |
0°C to 70°C
-40°C to 85°C
95% at 40°C, non-condensing |
|
Typical
Applications
|
|
Stopwatch
Mode
|
 |
The stopwatch
mode is used to time single events between
start and stop pulses on the same channel.
Duration of a single wave shape can be
measured by tying the A and B channels
together. |
|
Timing
Process Dynamics
|
 |
The start and
stop pulses used for timing can be generated
by the dual relays in a Laureate panel meter,
counter, or transmitter. For instance, the
start and stop pulse edges can be created as
temperature passes two alarm setpoints, or as
temperature cycles in a hysteresis control
mode. |
|
Replacing
an Oscilloscope with a Laureate Meter or
Transmitter
|
|

|
An oscilloscope
is great for viewing and timing pulses in a
lab. However, in fixed installations where
digital timing accuracy and control outputs
are required, a low-cost Laureate time
interval meter or transmitter will be the
instrument of choice. Resolution to 0.2 µs is
feasible. |
|
Instrumenting
a Pulsed Laser System
|
|

|
Some of the
many possibilities in instrumenting a
pulsed laser system with Laureate
dual-channel counters and transmitters:
elapsed time, number of pulses, pulse
width, pulse separation, duty cycle, and
pulse rep rate.
|
Click
to Order Stopwatch Input Modbus
Transmitter
|
|
Pinout
Laureate Serial
Output Transmitter
Stopwatch for Single Events or Accumulated Events
(shown with optional
analog output and dual relay output) |
|
|

|
|
Transmitter Powering a Single
Sensor
|
|

|
 |
| Transmitter
Powering Two Sensors |
Transmitter
with Active or Passive Sensors |
|
|
Click
to Order Stopwatch Input Modbus
Transmitter
|
|
|
|
|
FLW,
Inc - 3505
Cadillac Ave - Bldg E - Costa Mesa, CA. - 92626 - USA - Ph (714) 751 -
7512 - Fax (714) 751 - 0213
|
|
 |
 |
 |
|