Laurel Electronics
provides digital panel meters / controllers, totalizers, counters,
loop-powered meters, temperature meters, for all types of
transducers or process indication & control. |
| |
|
|
|
Load
Cell & Microvolt Input Modbus
or Laurel ASCII Protocol Serial I/O Transmitter
|

|

DIN Rail mounted, digitally programmable. Exceptional
accuracy at high update rates.
|
Click
to Order Load Cell & Microvolt Input Modbus Transmitter
|
|
Features |
Selectable Modbus or Laurel ASCII protocol. |
Modbus
RTU or ASCII modes, 2-wire connection, up to 247 digital
addresses. |
Digital
span adjust from 0 to ±99,999. |
Digital
zero adjust from -99,999 to +99,999. |
20,
50, 100, 250 & 500 mV full scale ranges. |
Peak
value capture and auto-tare. |
Output
accuracy: ±0.01% of full scale input. |
Update
rate: to 60/sec. |
Isolated
10V, 60 mA excitation supply to power up to two 350-ohm
load cells in parallel. |
4-
or 6-wire hookup to avoid
supply and lead resistance effects |
DIN
rail mount package only 22.5 mm thick. |
Powered
by AC or DC |
Detachable
screw-clamp connectors. |
|
Optional
isolated scalable analog output (4-20 mA or 0-10V). |
Optional
dual solid state relays for alarm or control. |
Optional
custom curve linearization (Extended main board). |
|
|
|
Description
|
| Signal
Types & Ranges. Laureate Modbus
I/O load cell or microvolt input transmitters are
designed for use with load cells, strain gauges
and microvolt input signals where exceptional sensitivity
and stability are required. A most sensitive full-scale
input range ±20 mV can be scaled to ±99,999 counts.
The selected input range for the full 0-20 mA output
span can be as wide as ±99,999 counts or as narrow
as 150 counts, limited only by considerations of
electrical noise and time constants of the programmable
moving average digital filter.
DIN
Rail Mounting.
Laureate transmitters are housed in a 35 mm DIN
rail case that is only 22.5 mm (0.89") thick.
Signal connections are via detachable screw clamp
plug connectors.
Modbus
Compliance.
Laureate Modbus transmitters are fully compliant
with Modbus over Serial Line Specification V1.0
(2002). This includes RTU or ASCII modes, 2-wire
connection, up to 247 digital addresses, and up
to 32 devices per RS-485 line without a repeater.
For microvolt DC or load cell signal inputs, output
accuracy is ±0.01% of full scale input, as provided
by the 16-bit analog-to-digital converter front
end. Full conversion accuracy is maintained
in the Modbus output. Advanced
standard features made possible with Modbus operation
include peak capture, auto-tare and latched relay
operation, since Reset can be provided via digital
commands.
Built-in
Load Cell Excitation
An
isolated 10 Vdc, 60 mA excitation supply rated
can power up to two 350-ohm load cells in parallel.
With 4-wire load connection, the transmitter operates
in a ratiometric mode to eliminate errors due
to supply variations. With 6-wire load connection,
it also compensates for variation in resistance
of the transducer leads, thereby allowing long
cable runs.
Fast
Read Rate
All
Laureate analog input meters and transmitters
use Concurrent Slope (Pat 5,262,780) analog-to-digital
conversion, which allows up to 50 or 60 conversions
per second, while integrating the signal over
a full power line cycle. High read rate is ideal
for peak capture and for real-time computer
interface and control.
Selectable
Signal Filtering
The internal
digital readings and analog output can be separately
selected to be either unfiltered or filtered.
-
An
unfiltered selection
updates after each conversion for fastest
response, up to 60/sec, while integrating
the input signal over a full power cycle.
Fast read rate provides true peak readings
and aids in control applications.
-
A
batch average filter selection
averages each 16 conversions for an update
every 1/4 sec.
-
An
adaptive moving average filter selection
provides a choice of 8 time constants from
80 ms to 9.6 s. When a significant change
in signal level occurs, the filter adapts
by briefly switching to the shortest time
to follow the change, then reverts back
to its selected time constant. Another choice
is Auto, which provides an automatic time
constant selection based on the signal noise
characteristics.
Easy
Setup & Scaling
Transmitter
programming is via
a three-terminal RS-232 port using Laurel's
PC-based Instrument
Setup Software. This software can be downloaded
from this website at no charge. The required
transmitter-to-PC interface cable is available
from Laurel (P/N CBL03). Laurel's serial output
transmitters and meters can also be part of
PC-based data logging systems using Laurel's
Datalogging
Software, which operates under the Laurel
ASCII Protocol. A single software command switches
between the Modbus and Laurel ASCII Protocols.
Scale
and offset can be set by either of two methods:
-
With
the coordinate reading method,
the Laureate reads the high and low signal
values, and the user enters the desired
high an low reading values. The Laureate
then calculates the span multiplier and
offset. This method is ideal if an external
calibration reference is available.
-
With
the manual coordinate method,
the user enters the high and low input values
in Volts plus the desired high and low reading
values. This method is suitable if no external
calibration reference is available.
Options
Options
include dual solid state relays for local alarm
or control and an isolated 4-20 mA or 10V (selectable)
analog output, effectively providing a linearized
analog transmitter output that tracks the reading
that would be transmitted digitally. The analog
output provides 12-bit (4096 step) resolution
of the output span and is ultra-linear to within
one bit. Its accuracy is ±0.05% of span for
all signal types, except for AC rms, where accuracy
is ±0.1%. Output isolation from signal and power
grounds is provided by a separate on-board power
supply, which can drive 20 mA into a 500 ohm
load for 10V compliance. Output isolation eliminates
problems caused by ground loops.
|
|
Click
to Order Load Cell & Microvolt Input Modbus
Transmitter
|
|
General Specifications- Laureate
Serial Output Transmitter, Load Cell or Microvolt
Input
(Click on links in previous section
for details by signal type) |
|
Analog Input |
Range |
Resolution |
Input Ohms |
Load Cell
|
±20.000 mV
±50.0000 V
±100.00 V
±250.00 V
±500.00 V |
-99,999 to
+99,999
zero adjust.
0 to ±99,999 span
adjust. |
1 Gohm |
|
Microvolt Meter |
±20.000 mV
±50.0000 V
±100.00 V
±250.00 V
±500.00 V |
1 µV
2.5 µV
5.0 µV
12.5 µV
25 µV |
1 Gohm |
|
Input
Resolution
Input Accuracy
Output Update Rate, Max
Max
Applied Voltage |
16 bits
(65,536 steps)
±0.01% of full scale input (determined by ADC).
50/sec at 50 Hz, 60/sec at 60 Hz.
100 V |
| Serial
I/O (standard) |
Signal
levels
Data Rates
Output Isolation
Serial Protocols
Devices on RS-485 Line
Modbus Addresses
Modbus Modes
Modbus Compliance |
RS485
(default) or RS232 (jumper selectable)
300, 600, 1200, 2400, 4800, 9600, 19200 baud
250V rms working, 2.3 kV rms per 1 min test.
Modbus RTU, Modbus ASCII, Laurel ASCII (selectable)
32 max without a repeater.
247 max
RTU or ASCII, 2-wire.
Modbus over Serial Line Specification V1.0 (2002). |
| Transducer
Excitation Output (standard) |
| Jumper
Selection 1
Jumper Selection 2
Jumper Selection 3 |
10V
@ 60 mA, isolated to 50V from signal ground
5V @ 50 mA, isolated to 50V from signal ground
15V @ 60 mA, non-isolated |
|
Dual Relay Output
(optional) |
|
Relay
Type
Load rating |
Two
solid state relays, SPST, normally open, Form A
120 mA at 130 Vac or 170 Vdc, 28 ohms series resistance. |
|
Analog Output
(optional) |
|
Output
Levels
Compliance, 4-20 mA
Compliance, 0-10V
Output Resolution
Output Accuracy
Output Isolation |
0-20
mA, 4-20 mA or 0-10 Vdc (selectable)
10V ( 0-500 ohm load )
2 mA ( 5 kOhm load )
12 bits (4,096 steps)
±0.05% of output span
250V rms working, 2.3 kV rms per 1 minute test |
| Power
Input |
|
Standard
power
Low power option
Frequency
Power Isolation |
95-240V
AC ±10% or 90-300V DC
12-30V AC or 10-48V DC
DC or 47-63 Hz
250V rms working, 2.3 kV rms per 1 min test. |
| Mechanical |
|
Case
Dimensions
Case Mounting
Electrical Connections |
120
x 101 x 22.5 mm.
35 mm rail per DIN EN 50022.
Detachable screw terminal connectors. |
| Environmental |
|
Operating
Temperature
Storage Temperature.
Relative Humidity |
0°C
to 70°C.
-40°C to 85°C.
95% at 40°C, non-condensing. |
Click
to Order Load Cell & Microvolt Input Modbus
Transmitter
|
|
Pinout
Process, Strain Gauge & Potentiometer
Follower Input
(shown with optional analog output and dual
relay output) |
|
|
|
Load
Cell Transmitter Connections |
|
|
|
In
4-wire connection,
the excitation and sense lines are tied
together. The meter can make ratiometric
corrections for supply voltage variations, but
not compensate for variations in lead
resistance. This connection is often used with
short cable runs. |
|
|
In
6-wire connection,
the sense lines are separate from the
excitation lines, thereby eliminating effects
due to variations in lead resistance. This
allows long cable runs in outdoor environments
with temperature extremes. |
|
|
For
large scales,
up to four 350 ohm load cells in parallel can
be powered by a single Laureate transmitter at
5V excitation. The excitation and sense points
of the four bridges are connected in parallel
through a summing box. |
|
Click
to Order Load Cell & Microvolt Input Modbus
Transmitter
|
|
|
|
|