Laurel Electronics provides digital panel meters / controllers, totalizers, counters, loop-powered meters, temperature meters, for all types of transducers or process indication & control.

 

 

 

 


Totalizer for 0-1 mA, 4-20 mAor 0-10V Signals 4-20 mA Current Transmitter


4-20 mA Current Transmitter and Totalizer for 0-1 mA, 4-20 mA and 0-10V Signals
Scalable for flow rate or total flow.DIN Rail mounted, digitally programmable


Click to Order 4-20 mA Totalizer


Features
Standard Main Board

Isolated 4-20 mA or 0-10V transmitter output, selectable.
Output tracks rate or total.
0-1 mA, 4-20 mA or 0-10V process signal input.
Output accuracy maintained for narrow or wide spans.
Selectable square root for differential flow.
5V, 10 V or 15V dc excitation output to power sensors.
Output resolution: 0.025% of span (12 bits).
Output accuracy: ±0.05% of span.
Output update rate: 25/sec.
DIN rail mount package only 22.5 mm thick.
Detachable screw clamp plug connectors.
Easy setup using Laurel's PC-based Instrument Setup Software.
Optional dual solid state relays for alarm or control.
 

Extended Main Board

All capabilities of the Standard Main Board, plus:
Custom curve linearization. Time based on rate (1/rate).

Description

Laureate 4-20 mA output, process signal input totalizing transmitters accept 0-1 mA, 4-20 mA or 0-10V signals from flow meters and other transducers, such as watt meters, to track rate or totalized rate.

  • With a Standard Main Board, the transmitter output can track rate (such as gallons per minute or watts) or totalized rate (such as gallons or kilowatt hours) whether the transducer output is linear or requires square root extraction (differential pressure flow transducers).
      

  • With an Extended Main Board, the transmitter can also perform custom curve linearization (provided by a curvilinear spline fit with up to 180 data points), display 1/ rate (such as the time it takes a conveyor to pass through an oven), and perform batch control for repetitive fill operations.  Such applications typically make use of optional dual solid state relays, which are available as options. External reset of totals is provided by a special connector.

The process transmitters convert the full-scale 0-1 mA, 4-20 mA or 0-10 V analog input signal to a frequency of 10-110 kHz, which is converted internally to a 6-digit rate reading rate using inverse period timing, and from there to the analog transmitter output. The analog output is accurate to ±0.05% of output span, as determined by an ultra-linear 12-bit (4096 step) digital-to-analog converter (DAC). The output update rate is a fast 25/sec. Output isolation from signal and power grounds is provided by a separate on-board power supply, which can drive 20 mA into a 500 ohm load for 10V compliance. Output isolation eliminates problems caused by ground loops. In addition to the 4-20 mA output that would typically be used for signal transmission in an industrial environment, a 0-10V analog output is selectable.

Transmitter programming is via a three-terminal RS-232 port using Laurel's PC-based Instrument Setup Software. This software can be downloaded from this website at no charge. The required transmitter-to-PC interface cable is available from Laurel (P/N CBL03).

The transmitters are housed in a DIN rail case that is only 22.5 mm (0.89") thick. Signal connections are via detachable screw clamp plug connectors.


Click to Order 4-20 mA Totalizer


specifications
Laureate 4-20 mA Transmitters
Analog Input Rate Transmitter & Totalizer

Analog Input 0-1 mA 4-20 mA 0-10 V
Input resistance
Max current or voltage
182 ohms
37 mA
9 ohms
160 mA
1 Mohm
600 V
Input Resolution
Span Tempco
Zero Tempco
Accuracy at 25°C
Read Rate

6 digits
±0.0025% R/°C
±0.0005 FS/°C
±0.005% FS ±1 count
25/sec (typical)

Analog Output
Output Levels
Compliance, 4-20 mA
Compliance, 0-10V
Output Resolution
Output Accuracy
Output Update Rate
Output Isolation
4-20 mA and  0-10 Vdc (selectable)
10V ( 0-500 ohm load )
2 mA ( 5 kOhm load )
12 bits (4,096 steps)
±0.05% of output span
25/sec
250V rms working, 2.3 kV rms per 1 minute test
Transducer Excitation Output (standard)
Jumper Selection 1
Jumper Selection 2
Jumper Selection 3
10V @ 60 mA, isolated to 50V from signal ground
5V @ 50 mA, isolated to 50V from signal ground
15V @ 60 mA, non-isolated
Dual Relay Output (optional)
Relay Type
Load rating
Two solid state relays, SPST, normally open, Form A
120 mA at 130 Vac or 170 Vdc, 28 ohms series resistance.
Power Input
Standard power
Low power option
Frequency
Power Isolation
95-240V AC ±10% or 90-300V DC
12-30V AC or 10-48V DC
DC or 47-63 Hz
250V rms working, 2.3 kV rms per 1 min test.
Mechanical
Case Dimensions
Case Mounting
Electrical Connections
120 x 101 x 22.5 mm
35 mm rail per DIN EN 50022
Detachable screw clamp plug connectors
Environmental
Operating Temperature
Storage Temperature
Relative Humidity
0°C to 70°C
-40°C to 85°C
95% at 40°C, non-condensing

Click to Order 4-20 mA Totalizer


Pinout
Laureate 4-20 mA Transmitters Analog Input Rate Transmitter & Totalizer
Pinout, 4-20 mA Current Transmitter and Totalizer for 0-1 mA, 4-20 mA and 0-10V Signals

DC & Externally Powered Process Transmitter

Transmitter Powering Two Sensors


Click to Order 4-20 mA Totalizer