Dual
Pulse Input Totalizer 4-20 mA Current Transmitter
|

|
Rate or total in same transmitter,
square root extraction.
DIN Rail mounted, digitally programmable.
|
Click
to Order Dual Pulse Input Totalizer
|
|
Features
Standard
Main Board
|
| Isolated
4-20 mA or 0-10V transmitter outputs, selectable. |
Pulse
input rates
to 1 MHz. |
| Two
independently field-scalable pulse input channels. |
Inputs
from NPN or PNP proximity switches, contact closures,
digital logic, magnetic pickups down to 12 mV, or AC
inputs up to 250 Vac. |
| Square
root extraction for differential pressure flow
transducers |
Internal
conversion of input to six-digit reading:
- Digital span adjust from 0 to ±999,999.
- Digital zero adjust from -999,999 to +999,999. |
| Up
counting from zero to preset value using positive scale
factor. |
Down
counting from preset to zero using negative scale
factor. |
| Output
resolution: 0.025% of span (12 bits). |
5V,
10 V or 15V dc excitation output to power sensors. |
| DIN
rail mount package only 22.5 mm thick. |
Detachable
screw clamp plug connectors. |
| Easy
setup using Laurel's PC-based Instrument
Setup Software. |
Optional dual solid state
relays for alarm or control. |
|
Features
Extended Main Board |
All
capabilities of the Standard Counter, plus:
|
- Channel
A total and Channel B rate simultaneously.
|
Up/down
counting on Channel A, using Channel B to control count
direction. |
- Counting
on Channel A, using Channel B to inhibit counting.
|
Arithmetic
functions A+B, A-B, AxB, A/B, A/B-1 (draw).
|
|
|
Description
|
|
Universal
Pulse or AC Input Signal Conditioner
Laureate
TM Series serial output, pulse input
totalizer transmitters accept two
independently scalable input channels from
a wide range of pulse sources, such as NPN
or PNP proximity switches, contact
closures, digital logic, magnetic pickups
down to 12 mV, or AC voltages to 250 Vac.
Input pulse rates can be as high as 1 MHz.
-
With
a Standard Main Board, the
transmitter output can be scaled to
engineering units, for example to
transmit totalized flow in gallons
from a flow meter output. Square root
extraction is standard.
-
With
an Extended Main Board,
the transmitter output can track rate
or totalized rate (such as gallons)
whether the transducer output is
linear, requires square root
extraction, or requires custom curve
linearization. The latter can be
provided by a curvilinear spline fit
with up to 180 data points. The
transmitter can also count up to a
preset total or down from a preset
total to zero. Such applications
typically make use of optional dual
solid state relays, which are
available as options. External reset
of totals can be via Modbus commands
or via a special three-position screw
terminal connector. The two input
channels A & B can also be
combined arithmetically to provide an
analog transmitter output that tracks
A+B (e.g., sum of two flows), A-B
(e.g., difference of two flows), AxB
(e.g., horsepower as product of force
and RPM), A/B (ratio of two flow), or
A/B-1 (draw or relative elongation of
material between rollers).
Exceptional
Accuracy and Stability
The
analog output is generated by an
ultra-linear 12-bit (4096 step)
digital-to-analog convert (DAC) whose
output span can be adjusted from 0 to ±999,999
counts and zero can be adjusted from
-999,999 to +999,999 counts. The analog
output has a rated accuracy of ±0.05%
of output span. The output update rate is
25/sec.
Transmitter
programming is via a three-terminal RS-232
port using Laurel's PC-based Instrument
Setup Software. This software can be
downloaded from this website at no charge.
The required transmitter-to-PC interface
cable is available from Laurel (P/N
CBL03).
The
transmitters are housed in a DIN rail case
that is only 22.5 mm (0.89") thick.
Signal connections are via detachable
screw clamp plug connectors
|
|
|
Click
to Order Dual Pulse Input Totalizer
|
|
General
Specifications
|
|
Pulse Input |
Types
Signal Ground
Minimum Signal
Maximum Signal
Maximum Frequency
Contact Debounce |
AC, pulses from NPN, PNP
transistors, contact closures, magnetic pickups.
Common ground for channels A & B.
Nine ranges from (-12 to +12 mV) to (+1.25 to +2.1V).
250 Vac
1 MHz, 30 kHz, 250 Hz (selectable).
0, 3, 50 ms (selectable). |
|
Transducer Excitation
Output (standard) |
Jumper Selection 1
Jumper Selection 2
Jumper Selection 3 |
10V @ 60 mA, isolated to 50V from signal
ground
5V @ 50 mA, isolated to 50V from signal ground
15V @ 60 mA, non-isolated |
|
Dual Relay Output
(optional) |
Relay Type
Load rating |
Two solid state relays, SPST, normally open,
Form A
120 mA at 130 Vac or 170 Vdc, 28 ohms series resistance. |
|
Analog Output
(optional) |
Output Levels
Compliance, 4-20 mA
Compliance, 0-10V
Output Resolution
Output Accuracy
Output Update Rate
Output Isolation |
4-20 mA and 0-10 Vdc (selectable)
12V ( 0-600 ohm load )
2 mA ( 5 kOhm load )
12 bits (4,096 steps)
±0.05% of output span
25/sec max
250V rms working, 2.3 kV rms per 1 minute test |
|
Power Input |
|
Standard power
Low power option
Frequency
Power Isolation |
95-240V AC ±10% or 90-300V DC
12-30V AC or 10-48V DC
DC or 47-63 Hz
250V rms working, 2.3 kV rms per 1 min test. |
|
Mechanical |
|
Case Dimensions
Case Mounting
Electrical Connections |
120 x 101 x 22.5 mm
35 mm rail per DIN EN 50022
Detachable screw clamp plug connectors |
|
Environmental |
|
Operating Temperature
Storage Temperature
Relative Humidity |
0°C to 70°C
-40°C to 85°C
95% at 40°C, non-condensing |
|
Typical
Applications
|
|
Up/Down
Totalizing
|
 |
Up/down
totalizing is provided by a mode of the
Extended totalizing transmitter where
pulses are either added or subtracted on
Channel A based on a direction input on
Channel B. The unit can also be
programmed so that counting by Channel A
is inhibited by an input on Channel B.
|
|
Combining
Two Totals
|
 |
A+B,
A-B, A/B and AxB arithmetic functions
are available with the Extended
totalizing transmitter. A+B can sum two
totals, while A-B subtracts the outflow
total from inflow total. A/B ratio
applied to two totals helps assure the
proper mixing of components.
|
|
Up
or Down Counting with Preset
|
 |
A
single Laureate dual-channel totalizing
transmitter will handle two repetitive
fill operations by counting from zero up
to a preset, or down from a preset to
zero. The dual relay option is required.
|
|
Machine
ON Time and Utilization
|
 |
An
easy way to measure the ON time of
machines is to count AC line cycles and
scale the total to hours. To display
machine utilization or duty cycle in
percent, use the Extended totalizing
transmitter. Connect Channel A to
switched AC and Channel B to the AC
line, and apply a 100 multiplier to the
A/B ratio.
|
|
Total
and Rate Simultaneously
|
 |
The
Extended version of the Laureate dual
channel totalizing transmitter can
transmit scaled rate or total for the
same channel at the push of a button,
and alarm both the rate and total. The
Extended version can also do curve
linearization, thereby extending the
working range and accuracy of flow
transducers.
|
|
|
Click
to Order Dual Pulse Input Totalizer
|
|
Pinout
Laureate 4-20 mA Transmitter, Dual
Pulse Input for Totalizing
(shown with optional analog output and dual
relay output)
|

|
|
Transmitter Powering a Single Sensor
|
|

|
 |
| Transmitter
Powering Two Sensors |
Transmitter
with Active or Passive Sensors |
|
Click
to Order Dual Pulse Input Totalizer
|
|
|
|
|
FLW,
Inc - 3505
Cadillac Ave - Bldg E - Costa Mesa, CA. - 92626 - USA - Ph (714) 751 -
7512 - Fax (714) 751 - 0213
|
|
 |
 |
 |
|