Laurel Electronics provides
digital panel meters / controllers, totalizers, counters, loop-powered meters,
temperature meters, for all types of transducers or process indication &
control. |
|
|
|
|
Laureate™
Dual-Setpoint Controller Options
With
contact or solid state relays, choice of control modes
|
|


|

|

|
| Dual
10 A relays |
Dual
solid state relays |
|
|
Features |
Isolated
dual-channel contact or solid state relay versions. |
Form
C contact relays rated 10 A at 250 Vac or 8 A at 24
Vdc. |
Solid
state relays rated 120 mA at 125 Vac or 250 mA at 0-150
Vdc. |
Outputs
derived from filtered or unfiltered signal input. |
NEMA-4X
(IP-65) front panel |
Fast
response time. |
Selectable
output time delay. |
Multiple
operating modes:
- output above or below setpoint
- latching or non-latching
- band deviation or hysteresis around each setpoint. |
|
Setpoint
setup via front panel pushbuttons or RS-232/485. |
Security
lockout of front panel setpoint controls. |
|
Certified
to UL 3101-1, CAN/CSA-C22.2, EN 61010-1 (CE Mark). |
--------- |
|
| Description |
| Contact
Relays or Solid State
Two optional plug-in setpoint controller boards
are available to add control and alarm capability to
Laureate DPMs, counters and remote displays:
A board with two Form C, 10 amp, 250 Vac contact
relays.
A board
with two Form A AC/DC solid state relays rated 120 mA
at 125 Vac or 250 mA at 150 Vdc. The solid state version
is recommended for high duty cycles and low-level loads.
Operating Modes
Operation above or below setpoint. Each relay
may be individually programmed to be energized above
or below a setpoint, or may be disabled.
Latching or non-latching. Each relay may be
individually programmed to operate in a latching or
non-latching mode. In the latching mode, when an alarm
or shutdown condition is reached, the output remains
in the alarm condition until it is reset by front panel
pushbuttons, via the serial interface, or via the rear
connector. In the non-latching mode, the output is automatically
reset when the alarm condition no longer exists.
Band deviation mode. Each relay may be set to operate
in a band deviation mode, where an alarm is generated
whenever the reading is a specified number of counts
above or below the setpoint. In particular, band deviation
is ideal to flag an out-of-tolerance condition.
Hysteresis mode. Each relay may be set to operate in
a hysteresis mode, where turn-on occurs at a specified
amount above the setpoint and turn-off occurs at the
same amount below the setpoint
Filtered or unfiltered input. Relay action may be derived
from either the filtered or unfiltered DPM input signals.
Using the unfiltered signal improves response time,
which is typically 17 ms for a DPM with the solid state
relay board. Fast response time is one of the major
strengths of Laureate DPMs, which can digitize analog
data as often as 60 times per second. Using the filtered
input reduces the chance of alarm triggering due to
noise.
Provisions for signal noise. A programmable time delay
and reduction of relay chatter can be achieved in the
DPM by selecting 1 to 128 readings in binary steps (20
ms to 2 s) prior to updating the output. Snubber circuitry
is part of the contact relay board to prolong contact
life. The relay response time of counters
is controlled by a selectable gate time from 10 ms
to 199.99 s.
Setup
Setpoint values and deviation bands are easily
entered via front panel pushbuttons or by computer via
the serial interface. Security lockout of the front
panel pushbuttons may be set to allow operators to view
but not change setpoint values. Front panel push-button
operation can also be completely disabled
The Laureate Weight Meter and Batch Controller offer
setpoint control modes beyond those of normal meter
or counter operation. |
|
|
Specifications |
| Operation |
Power
|
Provided
by meter |
Lockouts
|
May
be set to allow display and change of setpoint by front
panel pushbuttons, allow display only by alarm pushbutton,
or disable pushbuttons |
Update
Rate |
60
Hz or 50 Hz |
Input
Filtering |
Setpoint
compared to either filtered or unfiltered signal.
|
Setup
|
Front
panel pushbuttons or RS-232/485 |
Time
Delay |
Programmable
from 1 to 128 readings |
Operating
modes |
Available
for each output: operate above or below setpoint,
latching or non-latching, band deviation mode around
setpoint, hysteresis mode around setpoint, disabled.
|
---------- |
------------- |
| Alarm
Status Indication |
Type |
Two
red LED lamps |
Lamp
Lit |
When
relay is energized |
| Environmental |
Contact
Relay Version |
Operating
Temperature |
0°C
to 55°C |
Power
Rating |
AC
Load |
10
A at 250 Vac |
DC
Load |
8
A at 24 Vdc |
Storage
Temperature |
-40°C
to 85°C |
Isolation
to Signal & Meter Ground |
Isolation
Group |
C |
Rated
Voltage |
250
Vac |
Withstand
Voltage |
4.2
kVp for 1 min |
Relative
Humidity |
95%
at 40°C, non-condensing |
Response
Time to Input Signal |
DPM
Pickup Time |
26
ms typ (unfiltered) |
DPM
Release Time |
22
ms typ (unfiltered) |
Counter
Pickup or Release time |
Gate
time +30 ms +2 periods max |
| Solid
State Relay Version |
Power
Rating |
AC
loads |
120
mA at 125 Vac, 20 ohms series resistance. |
DC
loads |
2
loads, 250 mA, 0-150 Vdc peak hold-off, 5 ohms series
resistance.
4 loads, 120 mA, 0-150 Vdc peak hold-off, 10 ohms series
resistance. |
Isolation
to Signal & Meter Ground |
Isolation
Type |
Optical |
Safety
Rating |
250
Vac, 4.2 kVp per High Voltage Test |
|
Response
Time to Input Signal |
DPM |
17
ms typ (unfiltered) |
Counter |
Gate
time + 30 ms + 2 periods max |
|
|
Setpoint
Operating Modes |
|
Normal,
Non-Latched Operation |
|
|
In
this mode, the relay closes when the reading rises
above the setpoint and opens when the reading falls
below the setpoint. Relay ON/OFF control action
is independently programmable for each of the two
relays and can be reversed through a setup command.
|
|
Latched
Operation |
|
The
relay stays actuated until reset externally. This
mode can be used to shut down machinery or a process
when an operating limit has been exceeded, or to
maintain an alarm until acknowledged by an operator
when the alarm condition has passed. |
|
Mixed
Latched and Non-Latched Operation
|
|
One
of the relays can operate in a non-latched mode,
for instance to turn off a heater when an operating
temperature setpoint is reached. The other relay
can operate as a latching fail-safe backup and turn
off the entire process when a second, higher setpoint
is reached, indicating a malfunction. |
|
Deviation
Mode Operation
|
|
A
deviation limit (50 in this example) is set up around
both sides of the setpoint. The relay closes (or
opens) when the reading falls within the deviation
band, and opens (or closes) when the reading falls
outside of this band. This mode sets up a passband
around the setpoint and is often used for component
testing. |
|
Wide
Hysteresis Mode Operation
|
|
In this
example, a hysteresis limit of 600 is set below
the setpoint. The relay closes when the reading
reaches a lower limit (the setpoint less hysteresis)
and opens when the reading reaches an upper limit
(the setpoint).
One application
is automatic tank filling. A fill operation is automatically
initiated when the tank level has reached a lower
level and is terminated when the level has reached
an upper level.
|
|
Narrow
Hysteresis Mode Operation
|
|
Hysteresis
can be used to minimize the number of ON/OFF control
cycles around a setpoint, thereby increasing the
life of motors, relays, etc.
A very
narrow hysteresis band (such as 5 counts) can also
be used to minimize relay chatter around a setpoint
due to electrical noise on the signal, or due to
signal feedback caused by load switching. The hysteresis
limit should exceed the noise amplitude.
|
|
Electrical
Connections
|

Dual contact relays
Each load load rated 10 A at 250 Vac
or 8 A at 24 Vdc.
|

Solid state, AC or bidirectional DC connection
with 2 loads
Each load rated 120 mA at 125 Vac or 120 mA at 150 Vdc, 20
ohms series resistance
|

Solid state, DC connection with 4 loads
Each load rated up to 120 mA at 150 Vdc,
10 ohms series resistance.
|

Solid state, DC connection with 2 loads
Each load rated up to 250 mA at 150 Vdc,
5 ohms series resistance.
|
|
|
|
|