Laurel Electronics provides digital panel meters / controllers, totalizers, counters, loop-powered meters, temperature meters, for all types of transducers or process indication & control.



Laureate™ Power Options
For 85-264 Vac, or 8-28 Vac & 9-37 Vdc Input,with 5, 10 & 24 Vdc Excitation Output




Laureate Power Options

Laureate Power Options

85-264 Vac & 90-370 Vdc 8-28 Vac and 9-37 Vdc

Features

Lightweight, high-frequency switching power supply design.   
85-264 Vac or 90-370 Vdc input is standard. Includes 250 Vac, 0.1A resettable fuse.
Allows worldwide AC operation without hardware modification.
8-28 Vac or 9-37 Vdc power option.
Allows operation from batteries or 28 Vac, 400 Hz aircraft power. 
Three selectable isolated excitation outputs:
5 Vdc at 100 mA, 10 Vdc at 120 mA, or 24 Vdc at 50 mA. 
Certificate of compliance to UL 3101-1, CAN/CSA-C22.2, and EN 61010-1 safety standards.
Certification  issued by CSA, a Nationally Recognized Test Laboratory (File No. 212851).

Description

Laureate™ digital panel meters, digital counters and 6-digit remote display offer a choice of two high-frequency switching power supplies. These provide stable, isolated power for instrument operation plus excitation outputs at a substantially reduced weight and over a broader range of input voltages and power frequencies than conventional linear supplies

High voltage AC or DC power. The standard Laureate supply accepts power from 85 to 264 Vac, 47 to 440 Hz. This allows the same meter to operate worldwide without modification. The supply also accepts 90 to 370 Vdc.

Low voltage AC or DC power. An optional low voltage supply operates from 9 to 37 Vdc or 8 to 28 Vac, 47 to 440 Hz. This supply allows the Laureate to be powered from batteries or from 28 Vac, 400 Hz aircraft power

Isolated Excitation Output

Each power supply provides three jumper-selectable, isolated excitation outputs: 5 Vdc at 100 mA, 10 Vdc at 120 mA, or 24 Vdc at 50 mA. These outputs can be used to power external sensors, transmitters and up to four 350 ohm load cells, thereby avoiding the need for an expensive external supply. When powering a load cell or potentiometer, a ratiometric operating mode can be selected, where the meter monitors the excitation supply and removes the effects of voltage variation.

In addition to the isolated excitation output, regulated 5 Vdc at up to 50 mA is brought out and can be used to power external logic

Wiring of Excitation Output

4-wire 4-20 mA transmitter

4-wire 4-20 mA transmitter

4-wire 4-20 mA transmitter

4-wire 4-20 mA transmitter

With four-wire transmitters, two wires are used to apply 10 or 24 Vdc, and two separate wires are used to sense the transmitter's 4-20 mA output

With two-wire transmitters, the same two wires are used to power the transmitter and carry the 4-20 mA output, which is made to flow across an internal 10 ohm resistor between pins 3 and 4.

Both power supplies and their connectors (standard) are designed to UL/IEC/CSA safety standards. The two Laureate power supplies also do double-duty by providing two connector inputs (A & B) and a digital ground for signals such as meter hold, reset, tare, etc. These signals do not affect power supply operation.

Specifications

Operating Power Excitation Power Supply
Voltage (std)
85-264 Vac or 90-370 Vdc
Selectable outputs
5 Vdc ±5%, 100 mA max
10 Vdc ±5%, 120 mA max
24 Vdc ±5%, 50 mA max
Voltage (opt)

8-28 Vac or 9-37 Vdc

Ripple
50 mVp-p max
Frequency
DC and 49-440 Hz
Isolation to power ground
Safety-rated to 250 Vac, 4.2 kVp per High Voltage Test
Power consumption
5.3 W max
Isolation to meter ground
50 Vp
Pin Assignments